 AC-DC
250-450 Watts LP & LP-MD Series
* * * * * * *
xppower.com
Configurable for Fast Time to Market Industrial/IT & Medical Approvals All Outputs Isolated Low Profile 1U Applications Wide Voltage Adjustment Range SEMI F47 Certified Rugged Compact Design
Specification
Input
Input Voltage Input Frequency Inrush Current Power Factor * * * * 90-264 VAC 47-63 Hz 20 A pk max Compliant with EN61000-3-2
General
Efficiency Isolation * 75% typical at nominal input * 4000 VAC Input to Output 1500 VAC Input to Ground 50 VAC Output to Ground * AC OK, DC OK, Global & Module Inhibit. See signals & controls page * 890 kHrs demonstrated
Signals & Controls
Output
* See module table * 10 % min all modules. See module table for extended adjustment range Hold Up Time * 20 ms min Line Regulation * Typically 0.1%, maximum 0.3% Load Regulation * 1% max for single output modules & V1 of dual & triple output modules 2% max for V2 & V3 of dual & triple output modules A 10% load must be applied to output 1 of the high current dual module (U) & triple module (T) to achieve this figure Ripple & Noise * 50 mV or 1% pk-pk, whichever is greater, 20 MHz bandwidth Overvoltage Protection * 120-130% Vnom for single output & output 1 of high current dual modules (U) & triple modules (T) Overload Protection * <140% of nominal rating Short Circuit Protection * Foldback Temperature * 0.03%/C Coefficient Remote Sense * Compensates for up to 0.5 V drop on single (S) output modules & output 1 of dual (U) & triple (T) output modules Current Share * Single wire parallel current share. See signals & controls page Output Voltage Output Voltage Trim
MTBF
Environmental
Operating Temperature * 0 C to +70 C, derate linearly from 100% at +50 C to 50% at +70 C for fan versions. See airflow curves for U-channel versions. Storage Temperature * -40 C to +85 C Operating Altitude * 3000 m with no derating
EMC & Safety
Emissions * LP models P3-P5: EN55022, level B conducted LP-MD models, M3-M5: EN55011, level A conducted with FE(x) cover, level B conducted with ME(x) cover * EN61000-4-2, level 3 Perf Criteria A * EN61000-4-3, level 3 Perf Criteria A * EN61000-4-4, level 3 Perf Criteria A * EN61000-4-5, level 3 Perf Criteria A * EN61000-4-6, level 3 Perf Criteria A * EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B * LP models: EN60950, UL60950, CSA22.2 No 950, CE Mark LVD, SEMI F47 compliant (highline only) LP-MD models: EN60601-1, CSA22.2-601, UL60601-1, CE Mark LVD
ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals
AC-DC
Model Configuration
LP & LP-MD
STEP 1 In order to configure a model number for your LP (industrial) or LP-MD (medical) series power supply, first select the appropriate chassis based on your application's continuous, maximum output power requirements. Select `P' for industrial or `M' for medical. STEP 2 From the ratings below, select the output modules that suit your output voltage and current requirements. Modules can be positioned as denoted by the and sequence shown below. STEP 3 Form the model number as shown on the next page, ensuring you have selected a cooling method. P3 & M3 (250 W) Model Module Position 2 1 None None None P4 & M4 (350 W) Model Module Position 2 1 None None P5 & M5 (450 W) Model Module Position 2 1 None
Output Modules Voltage (Adjustment) & Current Ratings
OUTPUT 1 1.8 2.5 3.3 5.0 8.0 10.0 12.0 15.0 24.0 28.0 36.0 48.0 3.3 3.3 3.3 3.3 5.0 5.0 5.0 5.0 5.0 5.0 12.0 12.0 15.0 3.3 3.3 5.0 5.0 5.0 12.0 12.0 24.0 24.0 24.0 V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V (1.65-1.95 (2.25-2.75 (3.25-3.50 (4.50-5.50 (7.20-8.80 (9.00-11.00 (11.00-13.00 (14.00-16.00 (21.00-26.00 (25.00-31.00 (32.00-40.00 (43.00-53.00 (3.25-3.50 (3.25-3.50 (3.25-3.50 (3.25-3.50 (4.80-5.20 (4.80-5.20 (4.80-5.20 (4.80-5.20 (4.80-5.20 (4.80-5.20 (11.50-12.50 (11.50-12.50 (14.00-16.00 (3.25-3.50 (3.25-3.50 (4.80-5.20 (4.80-5.20 (4.80-5.20 (11.50-12.50 (11.50-12.50 (22.00-26.00 (22.00-26.00 (22.00-26.00 V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) V) @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ 50 50 50 50 31 25 20 17 10 9 7 5 40 40 40 40 40 40 40 40 8 8 6 6 5 20 20 20 20 20 10 10 4 4 4 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A OUTPUT 2 OUTPUT 3 MODULE CODE SZ S1 S2 S3 SF SG S4 S5 S6 S7 S8 S9 U5 U6 U7 U8 U1 U2 U3 U4 R6(1) R4(1) R1(1) R5(1) R2(1) T3 T4 T1 T2 T8 T6 T10 T11 T9 T7 MODULE SIZE ..
5.0 12.0 15.0 24.0 5.0 12.0 15.0 24.0 12.0 24.0 12.0 24.0 15.0 12.0 15.0 12.0 15.0 12.0 12.0 12.0 5.0 15.0 15.0
V V V V V V V V V V V V V V V V V V V V V V V
(4.8-16.0 (4.8-16.0 (4.8-16.0 (19.0-28.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (19.0-28.0 (11.5-12.5 (22.0-26.0 (11.5-12.5 (22.0-26.0 (14.0-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0
V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @
4.0 4.0 4.0 2.5 4.0 4.0 4.0 2.5 6.0 3.0 6.0 3.0 5.0 4.0 3.0 4.0 3.0 4.0 4.0 4.0 4.0 4.0 3.0
A A A A A A A A A A A A A A A A A A A A A A A
12.0 15.0 12.0 15.0 5.0 5.0 15.0 5.0 5.0 15.0
V V V V V V V V V V
(4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0 (4.8-16.0
V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @ V) @
4 3 4 3 4 4 3 4 4 3
A A A A A A A A A A
1. R modules do not have signals or control facilities. 2. Output V2 & V3 of U & T modules can supply up to 5 A in certain applications dependent on other rail loadings. Contact sales for details. 3. Also available from Farnell and Newark.
AC-DC
Preconfigured Models - Industrial
Output Power Max Output 1
5.0 V @ 50 A
LP
Output 3 Output 4 Industrial Version Model Number P3S3FE3 P3S4FE3 P3S6FE3 P3S9FE3 P4S3S3FE4 P4S4S4FE4 P4S3U6FE4 P4S3T6FE4 P5S4S4FE5 P5S3U6FE5 P5S3T6FE5 P5U4U6FE5
Output 2
250 W
12.0 V @ 20 A 24.0 V @ 10 A 48.0 V @ 5A 5.0 V @ 50 A 12.0 V @ 20 A 3.3 V @ 40 A 12.0 V @ 10 A 12.0 V @ 20 A 3.3 V @ 40 A 12.0 V @ 10 A 5.0 V @ 40 A 12.0 V (4.8-16.0 V) @ 4 A 12.0 V (4.8-16.0 V) @ 4 A 12.0 V (4.8-16.0 V) @ 4 A 5.0 V (4.8-16.0 V) @ 4.0 A 24.0 V (19.0-28.0 V) @ 2.5 A 12.0 V (4.8-16.0 V) @ 4 A 12.0 V (4.8-16.0 V) @ 4 A 5.0 V (4.8-16.0 V) @ 4.0 A 5.0 V @ 50 A
350 W
12.0 V @ 20 A 5.0 V @ 50 A 5.0 V @ 50 A 12.0 V @ 20 A 5.0 V @ 50 A 5.0 V @ 50 A 3.3 V @ 40 A
450 W
Model Number Example - Industrial (P) Versions
Chassis Power Module Position 2 Module Position 1 Fan Assembly Style Parallel Option
P3
Choose the chassis code first: P3 = 250 W Chassis P4 = 350 W Chassis P5 = 450 W Chassis Add any
S3
or module Add any e.g. S3 = Single 5 V
T1
or module e.g. T1 = Triple 5 V/12 V/12 V
FE3
Add fan cover assembly. e.g. FE3 = End fan assembly for 250 W chassis Leave blank for open U-channel
01
Add parallel option if required 2 x S module 1.8-15 V = 01 2 x S module 24-48 V = 02 Leave blank if not required
P3 Model
FE(x) End Fan
Screw terminal AC connections
NOTE: Model number format and module position may change dependent on module configuration chosen. Connector kits available. Order part number LP CONN KIT.
Fan Assemblies
Alternative fan assemblies are available. Consult sales for details. FTx Top Fan. Molex header AC connections End Fan. IEC AC connections
AC-DC
Preconfigured Models - Medical
Output Power Max Output 1
5.0 V @ 50 A
LP-MD
Output 3 Output 4 Medical Version Model Number M3S3ME3 M3S4ME3 M3S6ME3 M3S9ME3 M4S3S3ME4 M4S4S4ME4 M4S3U6ME4 M4S3T6ME4 M5S4S4ME5 M5S3U6ME5 M5S3T6ME5 M5U4U6ME5
Output 2
250 W
12.0 V @ 20 A 24.0 V @ 10 A 48.0 V @ 5A 5.0 V @ 50 A 12.0 V @ 20 A 3.3 V @ 40 A 12.0 V @ 10 A 12.0 V @ 20 A 3.3 V @ 40 A 12.0 V @ 10 A 5.0 V @ 40 A 12.0 V (4.8-16.0 V) @ 4 A 12.0 V (4.8-16.0 V) @ 4 A 12.0 V (4.8-16.0 V) @ 4 A 5.0 V (4.8-16.0 V) @ 4.0 A 24.0 V (19.0-28.0 V) @ 2.5 A 12.0 V (4.8-16.0 V) @ 4 A 12.0 V (4.8-16.0 V) @ 4 A 5.0 V (4.8-16.0 V) @ 4.0 A 5.0 V @ 50 A
350 W
12.0 V @ 20 A 5.0 V @ 50 A 5.0 V @ 50 A 12.0 V @ 20 A 5.0 V @ 50 A 5.0 V @ 50 A 3.3 V @ 40 A
450 W
Notes
1. Medical versions shown include EMC class B fan assembly.
Model Number Example - Medical (M) Versions
Chassis Power Module Position 2 Module Position 1 Fan Assembly Style Parallel Option
M3
Choose the chassis code first: M3 = 250 W Chassis M4 = 350 W Chassis M5 = 450 W Chassis Add any
S3
or module Add any e.g. S3 = Single 5 V
T1
or module e.g. T1 = Triple 5 V/12 V/12 V
ME3
Add fan cover assembly. e.g. ME3 = End fan assembly for 250 W chassis Leave blank for open U-channel
01
Add parallel option if required 2 x S module 1.8-15 V = 01 2 x S module 24-48 V = 02 Leave blank if not required
ME(x) End Fan
M3 Model
Screw terminal AC connections Class B
FE(x) End Fan
NOTE: Model number format and module position may change dependent on module configuration chosen. Connector kits available. Order part number LP CONN KIT.
Screw terminal AC connections Class A
Fan Assemblies
End Fan. IEC Dual-fused and switched AC connections. Class B End Fan. IEC AC connections. Class A Top Fan. Molex header AC connections
Alternative fan assemblies are available. Consult sales for details.
AC-DC
Signals & Controls
AC OK/Power Fail
When fitted in module position 2 of the chassis, pins 10 and 2 provide a minimum of 5 ms warning of loss of output regulation.
LP & LP-MD
Global Inhibit
Inhibiting the module fitted in position 2 will inhibit all outputs of other modules (fans remain running if fitted). If individual inhibit is required on the module fitted in chassis postion 2 alternative configurations are available. Please consult our application engineering team.
5V 330 AC OK (HIGH) PIN 10 INTERNAL TO PSU (Open Collector) PIN 2
Inhibit
Pins 6 and 2 (return) provide on/off control of the module. Applying a logic `0' between these pins turns the outputs off.
AC NOT OK (LOW)
OUTPUTS ON 5V OR FLOATING 0V OUTPUTS OFF
PIN 6
Current Share
Connecting pins 4 & 2 of like part number modules (3 maximum) within the same chassis or separate chassis will force the modules to current share the outputs.
PIN 2
(Reverse logic option available, i.e. high for outputs off or low for outputs on).
Module 1 Module 2 Module 3
Modules in Parallel
Pin 2 Pin 4 Pin 2 Pin 4 Pin 2 Pin 4
Single output modules with the same part number and V1 of dual and triple output modules can be paralleled to obtain increased output current. These modules can either be fitted in the same chassis or a different chassis with their outputs connected directly together and current share connections made, see Current Share.
DC OK
Pins 8 and 2 provide notification that the output voltage is within regulation via a logic 1.
Modules in Series
Single output modules can be connected in series to obtain alternate output voltages not available from a single module. For example a 10 V (SG module) can be connected in series with a 12 V (S4 module) to obtain an output voltage of 22 V.
5V 330 DC OK (HIGH) PIN 8 INTERNAL TO PSU (Open Collector) PIN 2
Remote Sense
Pins 1 (+ve) and 2 (-ve) provide compensation for voltage drops in application wiring up to a maximum of 0.5 V. Remote Sense is not fitted to (R) modules and V2 & V3 of (U) and (T) modules.
DC NOT OK (LOW)
Housekeeping
(Reverse logic option available, i.e. high for DC NOT OK). A 5 V standby voltage rated at 1 A is fitted to each chassis.
Notes 1. (R) module does not have these signal facilities.
AC-DC
Mechanical Details 250 Watt P3 & M3 Models U Channel
See Airflow Curves
8.00 (203.2) 1.50 (38.1) 0.75 (19.1) OUTPUT TERMINAL BLOCK M3.5 HARDWARE, 0.375 CENTRES 5.50 (139.7)
LP & LP-MD
Weight: 1.40 lb (0.64 kg) approx
+
-
+
5.00 (127.0)
3.50 (88.9)
LOGIC CONNECTOR AMP PN 102617-3 6-32 UNC THD OUTPUT HARDWARE OUTPUT HARDWARE 4X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION 8.30 (210.8) 1.50 (38.1) 5.50 (139.7)
A
FE3 Fan Assembly
Weight: 1.90 lb (0.86 kg) approx
+ A 1.50 (38.1) 0.75 (19.1) VIEW A-A AC INPUT CONNECTOR MOLEX PN 26-60-4050 MATING PLUG: MOLEX PN 09-50-3051 CONTACT: 18-20AWG, MOLEX PN 08-52-0072 1.50 (38.1) 5.50 (139.7) 2X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION
M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 1.56 (39.7) 9.50 (241.3)
.75 (19.1) 2.50 (63.5)
3.50 (88.9)
5.00 (127.0)
AIR FLOW
4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION
POWER SUPPLY OUTPUT TERMINATION AREA 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION
1.50 (38.1) 0.75 (19.1)
5.50 (139.7) AC INPUT 3 POSITION TERMINAL BLOCK L N GND
Notes 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm).
AC-DC
Mechanical Details 350 Watt P4 & M4 Models U-Channel
See Airflow Curves
9.00 (228.6) 1.50 (38.1)
LP & LP-MD
Weight: 1.50 lb (0.68 kg) approx
6.00 (152.4)
+
-
+
-
OUTPUT TERMINAL BLOCK M3.5 HARDWARE, 0.375 CENTRES
0.75 (19.1)
5.00 (127.0)
3.50 (88.9) A
LOGIC CONNECTOR AMP PN 102617-3
6-32 UNC THD OUTPUT HARDWARE
FE4 Fan Assembly
Weight: 2.00 lb (0.91 kg) approx
+ 4X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION A L N GND VIEW A-A AC INPUT CONNECTOR MOLEX PN 26-60-4050 MATING PLUG: MOLEX PN 09-50-3051 CONTACT: 18-20AWG, MOLEX PN 08-52-0072 1.50 (38.1) 0.75 (19.1) 1.50 (38.1) 6.00 (152.4) 2X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION
9.30 (236.2) M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 1.56 (39.7) 10.50 (266.7)
1.50 (38.1)
6.00 (152.4)
0.75 (19.1) 2.50 (63.5)
3.50 (88.9)
5.00 (127.0)
AIRFLOW
4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 6.00 (152.4) AC INPUT 3 POSITION TERMINAL BLOCK L N GND POWER SUPPLY OUTPUT TERMINATION AREA
1.50 (38.1) 0.75 (19.1)
Notes 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm).
AC-DC
Mechanical Details 250/350 Watt M3 & M4 ME3 Fan Assembly (M Models Only)
LP & LP-MD
Weight: 2.00 lb (0.91 kg) approx
8.30 (210.8) 1.50 (38.1) 5.50 (139.7)
M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 1.56 (39.7)
AC INPUT 3 POSITION TERMINAL BLOCK
POWER SUPPLY OUTPUT TERMINATION AREA
0.75 (19.1) 2.50 (63.5) L N GND
3.50 (88.9)
5.00 (127.0)
AIRFLOW
4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 10.25 (260.4) 1.50 (38.1) 5.50 (139.7) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION
0.75 (19.1)
ME4 Fan Assembly (M Models Only)
Weight: 2.16 lb (0.98 kg) approx
9.30 (236.2) 1.50 (38.1) 6.00 (152.4)
M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 1.56 (39.7) AC INPUT 3 POSITION TERMINAL BLOCK
POWER SUPPLY OUTPUT TERMINATION AREA
0.75 (19.1) 2.50 (63.5) 5.00 (127.0) L N GND
3.50 (88.9)
AIRFLOW
4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION
11.25 (285.8)
1.50 (38.1) 0.75 (19.1)
6.00 (152.4)
2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION
Notes 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm).
AC-DC
Mechanical Details 450 Watt P5 & M5 Models
450 Watts - P5 and M5 models are always shipped with a fan cover to ensure adequate cooling.
LP & LP-MD
Weight: 2.50 lb (1.14 kg) approx
FE5 Fan Assembly
1.68 (42.5)
1.50 (38.1) 0.75 (19.1)
6.00 (152.4)
10.50 (266.7)
3.50 (88.9)
5.00 (127.0)
AIR FLOW
L N GND
LNG
4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 1.50 (38.1) 0.75 (19.1) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 8.00 (203.2)
AC INPUT 3 POSITION TERMINAL BLOCK
POWER SUPPLY OUTPUT TERMINATION AREA
ME5 Fan Assembly (M Models Only)
Weight: 2.62 lb (1.19 kg) approx
M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 9.80 (248.9) 1.50 (38.1) 0.75 (19.1) 2.50 (63.5) L N GND 6.00 (152.4) 1.68 (42.5) AC INPUT 3 POSITION TERMINAL BLOCK
POWER SUPPLY OUTPUT TERMINATION AREA
3.50 (88.9) 5.00 (127.0)
AIR FLOW
4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 11.75 (298.5) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 1.50 (38.1) 0.75 (19.1) 8.00 (203.2)
Notes 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm).
AC-DC
Airflow Curves - U-Channel Models
The curves denote chassis derating. Output modules must be derated by the same proportion.
Formula for converting CFM to LFM: LFM = CFM x 144 (total cross section of airflow path (Inches2)) CFM =
LP & LP-MD
Formula for converting LFM to CFM: LFM x (total cross section of airflow path (Inches2)) 144
P3 & M3 Models
300 250 400 350
P4 & M4 Models
Power (Watts)
200 150 100 50 0 0 25 50 70
300 LFM 225 LFM 150 LFM Convection
Power (Watts)
300 250 200 150 100 50 0 0 25 50 70
Temperature (C)
Temperature (C)
Output Module Connection Details
Single Output (S)
VOLTAGE ADJUST (BEHIND) LOGIC CONNECTOR
Weight: 0.50 lb (227 g) approx
M4-0.7 THD OUTPUT TERMINALS
OUTPUT TERMINAL BLOCK M3.5 0.375 CENTERS LOGIC CONNECTOR VOLTAGE ADJUST
+
+
10 2
10 2
9
1
9
1
Logic Connector AMP 87631-5 Pin Function 1 +sense (V1) 2 -sense (V1) 3 +sense (V1) 4 Current share 5 6 Inhibit 7 -sense (V1) 8 DC OK 9 Module Size 10 Power fail
Dual Output (R)
OUTPUT TERMINAL BLOCK 6-32 0.375 CENTERS OUTPUT 2 OUTPUT 1
Weight: 0.52 lb (236 g) approx
+
-
+
-
VOLTAGE ADJUST
Module Size Weight: 0.62 lb (282 g) approx
Logic Connector AMP 87631-5 Pin Function 1 +sense (V1) 2 -sense (V1) 3 +sense (V1) 4 Current share 5 6 Inhibit 7 -sense (V1) 8 DC OK 9 10 Power fail Module Size Logic Connector AMP 87631-5 Pin Function 1 +sense (V1) 2 -sense (V1) 3 +sense (V1) 4 Current share 5 6 Inhibit 7 -sense (V1) 8 DC OK 9 10 Power fail Module Size
Dual Output (U)
V2 MATING CONNECTOR MOLEX 39-01-2025 VOLTAGE ADJUST (BEHIND)
V1
+
V2
10
2
+ 9 1
LOGIC CONNECTOR V1 OUTPUT TERMINAL BLOCK (EUROSTYLE 10.16mm) WIDE RANGE: 6 TO 18 AWG WIRE STRIP LENGTH: 0.25" (6.35mm) TIGHTENING TORQUE: 7 IN-lbs
Triple Output (T) Weight: 0.70 lb (318 g) approx
OUTPUT TERMINAL BLOCK 6-32 0.375 CENTERS OP 1 VOLTAGE ADJUST (BEHIND) LOGIC CONNECTOR 6 4 MULTI-OUTPUT POWER CONNECTOR
+
10
2
Output Connector Molex 39-01-2060 Pin Function 1 Output RTN V2 2 3 Output RTN V3 4 Output 2+ 5 6 Output 3+
9
1
3
1 OP 2 VOLTAGE ADJUST
OP 3 VOLTAGE ADJUST
17-Apr-07


▲Up To Search▲   

 
Price & Availability of M5S3T6ME5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X